cswork / libraryOpen practice workspace

Interview guides · Edison Energy

Edison Energy Software Engineer Interview Guide

Edison Energy Software Engineer interview guide: reported rounds, questions and how candidates describe the process.

The 60-second brief

The role of a Software Engineer at Edison Energy is pivotal to driving innovation and efficiency within the energy sector. This position focuses on developing robust software solutions that enhance energy management systems, optimize operational processes, and support the company's mission to provide sustainable energy solutions. As a Software Engineer, you will engage in projects that tackle complex challenges, such as improving HVAC systems, integrating renewable energy sources, and streamlining data management across various platforms. Your work will directly impact the effectiveness of our products, influencing how energy is consumed and managed by our clients. By employing cutting-edge technologies and methodologies, you'll contribute to strategic initiatives that not only elevate Edison Energy's offerings but also promote a sustainable future.

This guide is scoped to a Software Engineer candidate at Edison Energy.

Focus areas

  • Practical Engineering Knowledge (Energy & HVAC)
  • Technical Interview (Practical Knowledge)
  • Problem Solving

The Edison Energy interview process

Edison Energy candidates report 3 rounds over 3-5 weeks. The stages below are what candidates describe, not a published process.

Phone Screening

Initial phone screening to assess candidate's background and fit for the role.

What to demonstrate

  • Initial phone screening to assess candidate's background and fit for the role
  • Depth in Practical Engineering Knowledge (Energy & HVAC)

How to prepare

  • Be able to walk your CV end to end in two minutes, and say why this company specifically.
  • Have your salary expectations, notice period and location constraints ready, and ask for the rest of the loop in writing.

Technical Interview

Interviews focusing on technical competencies, including problem-solving and domain knowledge.

What to demonstrate

  • Interviews focusing on technical competencies
  • Including problem-solving and domain knowledge

How to prepare

  • Answer aloud and timed: Describe a challenging technical problem you faced in a previous project and how you resolved it.
  • Answer aloud and timed: How do you ensure the reliability and performance of a software application?

Behavioral Interview

Assessment of interpersonal skills, teamwork, and cultural fit within Edison Energy.

What to demonstrate

  • Assessment of interpersonal skills, teamwork, and cultural fit within Edison Energy
  • Depth in Practical Engineering Knowledge (Energy & HVAC)

How to prepare

  • Prepare three examples from your own work, each with a decision you made and an outcome you can quantify.
  • Re-read the description of the behavioral interview above and write down what you would ask to confirm before it.

Where candidates lose points

Understand the Mission

Familiarize yourself with Edison Energy's commitment to sustainability and how your role can contribute to this vision.

Communicate Clearly

Practice articulating your thoughts and solutions clearly, especially during technical discussions.

Prepare Real-World Examples

Think of specific projects or experiences that demonstrate your skills and how they align with the role.

Questions & practice

Diff a projection against the primary without per-row point reads

Hard · reconciliation · range hashing · throttling

The listing projection has drifted and some rows show a stale version. The primary holds 40,000,000 resource rows across 12,000 tenants while serving 1,200 writes and 14,000 reads per second. The obvious repair, reading each resource row and comparing its version against the projection, is correct and would eventually finish. Explain precisely why it is unacceptable here, then give a diff that finds the differing rows, state its complexity, and make it safe to run against a live primary. Replication lag is usually under 100 ms and is not bounded.

Approach

  1. Quantify the naive cost rather than calling it slow: 40,000,000 point reads at even 0.5 ms each is over five hours serialised, and the only lever is concurrency, which is exactly what you cannot spend. The primary's pool is sized for the write path, and 40,000,000 random reads evict the buffer cache that sustains the 85 percent cache hit rate, so the audit degrades the system it is auditing.
  2. Replace random access with one ordered pass per side. Both sides can be read in (tenant_id, resource_id) order, which is a sequential scan on each and a merge join in O(n) time and O(1) memory. For a dense diff that is the whole answer, and it reads the primary once instead of 40,000,000 times.
  3. For the expected sparse case, compare range hashes instead of rows: partition the key space, compute per range an order-independent aggregate over hash(resource_id, version), compare aggregates, and descend only into ranges that differ. With d differing rows and branching factor B, at most d ranges mismatch per level, so the drill-down examines O(d log_B(n/d)) ranges and reads full rows only in mismatching leaves.
  4. Aggregate with a sum modulo 2^64 or a multiset hash, never XOR. XOR is order-independent but self-cancelling, so two rows wrong in the same way, or a row duplicated on one side, leave the range aggregate matching and the range is declared clean.

Follow-up

  • The diff reports 900 stale rows. How do you decide between patching those rows and rebuilding the projection from resource_revision?
  • Same job, but the projection lives in a search index that cannot be scanned in key order. What changes?

Merge partitioned event streams into one ordered feed with bounded lateness

Hard · k-way merge · watermarks · out-of-order streams

The read-model service consumes 64 log partitions carrying about 4,000 events per second in total. Each partition is ordered within itself, but partitions drift by up to 30 seconds, and the activity feed must present a tenant's events in occurred_at order. Produce the merge. State its complexity, the buffer it requires in events and in bytes, what happens when one partition is idle, and what you do with an event that arrives after you have already emitted its position. Payloads average 1 KB.

Approach

  1. Merge with a min-heap over the 64 partition heads keyed on (occurred_at, event_id): O(log P) per event and O(n log P) overall. The tie-break on event_id is what makes the output deterministic when two partitions carry the same millisecond, which matters because the feed is paginated and a non-deterministic order reorders pages under the reader.
  2. Emitting the heap head is only correct once every partition has produced everything up to that timestamp, so the emit condition is a watermark: the minimum across partitions of the highest occurred_at seen, less the allowed lateness. Events are held until the watermark passes them, which is what turns individually ordered streams into a jointly ordered one.
  3. Size the buffer from the lateness rather than guessing: 4,000 events per second times 30 seconds is 120,000 buffered events, and at 1 KB each about 120 MB of heap. That number is the real price of the ordering guarantee and belongs in front of whoever asked for it.
  4. Handle the idle partition explicitly, because it fails the feed rather than corrupting it: a partition with no traffic never advances its own maximum, so the watermark freezes and output stops entirely. Either every partition emits a periodic idle marker carrying the broker's current time, or the watermark falls back to wall clock for a partition silent beyond a threshold.

Follow-up

  • The lateness budget is raised to five minutes. What is the new buffer, and what besides memory changes?
  • The consumer restarts. Where does it resume from, and what does the feed look like for the first 30 seconds?

Archive a resource graph without breaking live references or recursing

Medium · graph traversal · topological order · tenant isolation

Resources reference other resources within a tenant; for the largest tenant the reference table holds up to 2,000,000 nodes and 8,000,000 edges. Archiving a resource must archive everything reachable from it that nothing outside the set still references, refuse when a live external referrer exists, and terminate when references form cycles, which they legitimately do. Produce the archive order and the refusal list, targeting O(V+E). Say what stops the traversal crossing a tenant boundary, and why recursion is the wrong control structure at this size.

Approach

  1. Load the subgraph with the tenant predicate on both endpoints of the edge, not only on the side you started from. Scoping the left table alone is the classic cross-tenant leak: one mis-entered edge then pulls another tenant's resources into the traversal and, worse, into the archive.
  2. Traverse iteratively with an explicit stack. A 2,000,000-node graph can hold a chain deep enough to exhaust a native stack in the low tens of thousands of frames, and that failure is a process crash rather than an error you can return.
  3. Treat cycles as data rather than corruption: compute strongly connected components with Tarjan in O(V+E) using its own explicit stack, then condense. The condensation is a DAG, so a topological order over it gives the archive order, and every member of a component archives in one transaction because no order within a cycle is valid.
  4. Decide refusals with reverse edges. A candidate is archivable only if every in-edge originates inside the candidate set, so build the transpose or count in-degrees restricted to the visited set, and emit each blocked resource with the id of the external referrer, which is the only part of the answer an operator can act on.

Follow-up

  • The graph is read in one query and the archive writes a minute later. What can change in between, and how do you make the write safe?
  • The candidate set is 400,000 resources. Is that one transaction, and if not, what does a half-finished archive look like to a reader?

Hold a per-tenant active cap against concurrent creates

Hard · write skew · isolation levels · constraints

A tenant on the standard plan may hold at most 50 resources with status='active'. The create handler runs SELECT count(*) FROM resource WHERE tenant_id = $1 AND status = 'active', compares to 50, then inserts. Two creates arrive 3 ms apart on different instances and the tenant lands at 51. Name the anomaly, say whether PostgreSQL 16 READ COMMITTED or REPEATABLE READ prevents it and why, then give an implementation that holds the cap at READ COMMITTED with the exact statements. Finally, say what changes when the cap is 'at most one running export per tenant' on job_run.

Approach

  1. Name it: write skew. The two transactions read an overlapping set and write disjoint rows, so there is no row-level conflict for the engine to detect and each commit is individually legal.
  2. Rule out the levels precisely. READ COMMITTED takes a fresh snapshot per statement and takes no lock on the counted rows, so both see 49. PostgreSQL's REPEATABLE READ is snapshot isolation: it removes non-repeatable reads and phantoms within the snapshot but still admits write skew, because the anomaly is not a re-read of a changed row, it is a read of a set that a concurrent transaction invalidates. Only SERIALIZABLE closes it, by tracking the read dependency and aborting one transaction with SQLSTATE 40001 — a guarantee that exists only if the application re-runs the whole transaction from the read.
  3. Convert the set predicate into a single-row conflict: keep tenant.active_resource_count and run UPDATE tenant SET active_resource_count = active_resource_count + 1 WHERE tenant_id = $1 AND active_resource_count < 50 in the same transaction as the INSERT. Zero affected rows is the cap, returned as 409. The row lock serialises the decision at any isolation level, and contention is bounded to one tenant's row — which is also the fair-scheduling unit, unlike a global counter that would convoy every tenant behind one row.
  4. State the cost you just took on: a counter is a second source of truth that can drift, so every path that changes status must adjust it inside the same transaction, and a periodic reconciliation has to exist, with resource_revision as the authority for what the count should have been.

Follow-up

  • A resource moves from archived back to active. Which statements change, and what breaks if the counter update and the status change land in different transactions?
  • The cap becomes plan-dependent and a plan can change mid-month. Where does the number 50 live, and who reads it?

Stop tag and share joins from fanning out a page

Medium · join fan-out · semi-joins · many-to-many

resource_tag is (resource_id, tag_id) with PK (resource_id, tag_id); resource_share is (resource_id, shared_with_user_id, permission). The tagged-and-shared listing inner-joins resource to both, filters tenant_id, tag_id = ANY($2) and shared_with_user_id = $3, orders by updated_at DESC and takes 50. Pages come back with fewer than 50 distinct resources and the total in the header is far too high. Explain the row multiplication, rewrite both the page query and the count query so each is correct, and name the index each one needs. PostgreSQL 16.

Approach

  1. Do the arithmetic against the predicates that are actually there. An inner join emits one row per matching child row, and both joins are filtered: tag_id = ANY($2) admits only the requested tags, shared_with_user_id = $3 admits one user's share rows. So a resource holding three of the requested tags and shared with $3 once yields three rows, not one — the multiplier is its count of matching tags times its share rows for that single user, and that second factor is 1 unless the table admits duplicate (resource_id, shared_with_user_id) pairs. LIMIT 50 then limits rows rather than resources, and COUNT(*) counts pairs — the header is the product, not the population.
  2. Reject DISTINCT as the fix. It deduplicates after the product has been built, so the planner must materialise and sort the fanned-out set before the LIMIT can apply, and it leaves any SUM or AVG in the same select list wrong.
  3. Rewrite both filters as semi-joins, keeping resource as the only row source: AND EXISTS (SELECT 1 FROM resource_tag rt WHERE rt.resource_id = r.resource_id AND rt.tag_id = ANY($2)) and the same shape against resource_share. A semi-join stops at the first match per resource and preserves the driving index order, so ORDER BY updated_at DESC, resource_id DESC LIMIT 50 still stops after 50 rows.
  4. Count with the same predicates and no join at all: SELECT count(*) FROM resource r WHERE r.tenant_id = $1 AND r.status = 'active' AND EXISTS (...) AND EXISTS (...). Nothing multiplies a resource, so the number is the population.

Follow-up

  • The filter changes from 'any of these tags' to 'all of these tags'. Rewrite it and state what it costs relative to the ANY form.
  • A resource can be shared with the same user twice under different permissions. Does your count change, and should it?

What are the key components of a building's HVAC system, and how do they interact?

Medium · Technical / Domain Questions

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

Explain how you would approach optimizing an energy management system for a commercial building.

Medium · Technical / Domain Questions

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

Describe a challenging technical problem you faced in a previous project and how you resolved it.

Medium · Technical / Domain Questions

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

How do you ensure the reliability and performance of a software application?

Medium · Technical / Domain Questions

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

What programming languages and frameworks do you find most effective for energy-related applications?

Medium · Technical / Domain Questions

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

How would you prioritize features for a new software application aimed at improving energy efficiency?

Medium · Problem-Solving / Case Studies

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

Given a scenario where energy consumption unexpectedly spikes, how would you investigate the root cause?

Medium · Problem-Solving / Case Studies

Approach

  1. Establish what changed and when, before forming any theory.
  2. Pick a bisection that eliminates candidates whichever way it turns out.
  3. Check the instrumentation before believing the symptom.
  4. Separate the trigger from the cause; the deploy is rarely the bug.

Follow-up

  • What would you look at first, and what would it rule out?
  • How would you tell a cause from a coincidence here?

Suggested practice checklist

Built from the rounds and topics Edison Energy candidates report.

Day 1 — Map the Edison Energy loop

  • Write out the reported sequence: Phone Screening, Technical Interview, Behavioral Interview.
  • For each round, write one sentence on what it is judging, from the description above, and mark the one you are least ready for.

Deliverable: A one-page map of the 3 reported rounds, with the weakest marked.

Day 2 — Work Practical Engineering Knowledge (Energy & HVAC)

  • Spend the session on Practical Engineering Knowledge (Energy & HVAC), which Edison Energy candidates report being tested on.
  • Write one worked example in Practical Engineering Knowledge (Energy & HVAC) and time yourself on it.

Deliverable: One timed worked example in Practical Engineering Knowledge (Energy & HVAC).

Day 3 — Work Technical Interview (Practical Knowledge)

  • Spend the session on Technical Interview (Practical Knowledge), which Edison Energy candidates report being tested on.
  • Write one worked example in Technical Interview (Practical Knowledge) and time yourself on it.

Deliverable: One timed worked example in Technical Interview (Practical Knowledge).

Day 4 — Work Problem Solving

  • Spend the session on Problem Solving, which Edison Energy candidates report being tested on.
  • Write one worked example in Problem Solving and time yourself on it.

Deliverable: One timed worked example in Problem Solving.

Day 5 — Answer out loud: Technical / Domain Questions

  • Answer aloud, timed: What are the key components of a building's HVAC system, and how do they interact?
  • Answer aloud, timed: Explain how you would approach optimizing an energy management system for a commercial building.

Deliverable: Spoken answers to 2 reported Technical / Domain Questions question(s), under time.

Day 6 — Answer out loud: Problem-Solving / Case Studies

  • Answer aloud, timed: Given a scenario where energy consumption unexpectedly spikes, how would you investigate the root cause?
  • Answer aloud, timed: How would you prioritize features for a new software application aimed at improving energy efficiency?

Deliverable: Spoken answers to 2 reported Problem-Solving / Case Studies question(s), under time.

Day 7 — Answer out loud: Behavioral / Leadership

  • Answer aloud, timed: Tell me about a time you worked on a team project. What was your role, and how did you contribute to the team's success?
  • Answer aloud, timed: How do you handle conflicts with team members or stakeholders?

Deliverable: Spoken answers to 2 reported Behavioral / Leadership question(s), under time.

Behavioural preparation

Behavioural rounds judge the decision you made and what it cost.

Describe a time when you had to make a trade-off between performance and cost in a project.

Medium · Problem-Solving / Case Studies

Approach

  1. Pick a story where you made the decision, not one where you watched it.
  2. State the situation in two sentences and spend the rest on the reasoning.
  3. Give the blast radius: what could have broken, and what you measured.
  4. Name the disagreement and how you resolved it with evidence.

Follow-up

  • What would you do differently if you ran that again?
  • How did you know your change caused the improvement?

Tell me about a time you worked on a team project. What was your role, and how did you contribute to the team'

Medium · Behavioral / Leadership

Tell me about a time you worked on a team project. What was your role, and how did you contribute to the team's success?

Approach

  1. Pick a story where you made the decision, not one where you watched it.
  2. State the situation in two sentences and spend the rest on the reasoning.
  3. Give the blast radius: what could have broken, and what you measured.
  4. Name the disagreement and how you resolved it with evidence.

Follow-up

  • What would you do differently if you ran that again?
  • How did you know your change caused the improvement?

How do you handle conflicts with team members or stakeholders?

Medium · Behavioral / Leadership

Approach

  1. Pick a story where you made the decision, not one where you watched it.
  2. State the situation in two sentences and spend the rest on the reasoning.
  3. Give the blast radius: what could have broken, and what you measured.
  4. Name the disagreement and how you resolved it with evidence.

Follow-up

  • What would you do differently if you ran that again?
  • How did you know your change caused the improvement?

Describe a situation where you had to adapt to significant changes during a project.

Medium · Behavioral / Leadership

Approach

  1. Pick a story where you made the decision, not one where you watched it.
  2. State the situation in two sentences and spend the rest on the reasoning.
  3. Give the blast radius: what could have broken, and what you measured.
  4. Name the disagreement and how you resolved it with evidence.

Follow-up

  • What would you do differently if you ran that again?
  • How did you know your change caused the improvement?