cswork / libraryOpen practice workspace

Interview guides · EDF

EDF Software Engineer Interview Guide

EDF Software Engineer interview guide: reported rounds, questions and how candidates describe the process.

The 60-second brief

As a Software Engineer at EDF, you play a vital role in ensuring the reliability and efficiency of our energy systems. Your work directly impacts the development and implementation of software solutions that optimize energy generation, distribution, and management. This position is not just about coding; it’s about contributing to sustainable energy solutions that fuel the future, helping us navigate the complexities of the energy sector while maintaining our commitment to safety and innovation. You will be involved in diverse projects that may include enhancing SCADA systems, developing software for renewable energy solutions, or contributing to nuclear energy management systems. Each project requires a blend of technical expertise, problem-solving skills, and collaboration with multidisciplinary teams.

This guide is scoped to a Software Engineer candidate at EDF.

Focus areas

  • Nuclear industry domain knowledge
  • Power plant operations overview (nuclear centrale process)
  • Earned Value Management (EVM) / comprehension of Value Acqui

The EDF interview process

EDF candidates report 4 rounds over 3-5 weeks. The stages below are what candidates describe, not a published process.

Initial Screening

Conducted by HR to evaluate candidate's background and fit for the role.

What to demonstrate

  • Conducted by HR to evaluate candidate's background and fit for the role
  • Depth in Nuclear industry domain knowledge

How to prepare

  • Be able to walk your CV end to end in two minutes, and say why this company specifically.
  • Have your salary expectations, notice period and location constraints ready, and ask for the rest of the loop in writing.

Technical Interviews

Interviews with team leaders and potential peers focusing on technical expertise.

What to demonstrate

  • Interviews with team leaders and potential peers focusing on technical expertise
  • Depth in Nuclear industry domain knowledge

How to prepare

  • Answer aloud and timed: Describe your experience with CI/CD practices and tools.
  • Answer aloud and timed: What are the key considerations when developing software for energy management systems?

Practical Coding Exercises

Candidates complete coding exercises to demonstrate their skills in context.

What to demonstrate

  • Candidates complete coding exercises to demonstrate their skills in context
  • Depth in Nuclear industry domain knowledge

How to prepare

  • Answer aloud and timed: How do you ensure code quality and maintainability?
  • Answer aloud and timed: Describe a challenging team project you worked on. What was your role, and how did you contribute to its success?

Discussions About Past Projects

Candidates discuss their previous work to showcase relevant experience.

What to demonstrate

  • Candidates discuss their previous work to showcase relevant experience
  • Depth in Nuclear industry domain knowledge

How to prepare

  • Answer aloud and timed: How do you handle conflicts or disagreements within a team?
  • Answer aloud and timed: Can you provide an example of how you adapted to a significant change in a project?

Where candidates lose points

Research the Company

Understand EDF's mission, values, and current projects. Familiarity with recent news or initiatives can help you align your responses with the company's goals.

Practice Behavioral Questions

Use the STAR method (Situation, Task, Action, Result) to structure your responses to behavioral questions, providing clear and concise examples from your experience.

Show Enthusiasm for the Energy Sector

Articulate why you are interested in working for EDF and how you can contribute to its mission in the energy sector.

Prepare for Technical Assessments

Brush up on relevant technical skills and be ready to demonstrate your coding abilities or problem-solving processes during practical assessments.

Questions & practice

Track a rolling failure rate per destination for circuit decisions

Easy · sliding window · ring buffer · circuit breaker

The egress service delivers about 1,500 webhooks per second across roughly 40,000 destinations, each call bounded by a 10 second timeout. Maintain, per destination, the failure rate over the trailing 60 seconds so a caller can ask before dispatch whether the circuit should open. Attempts arrive as (destination_id, finished_at_ms, outcome). Requirement: amortised O(1) per attempt, with total memory bounded by the destination count rather than by traffic. Give the structure, its exact memory, and the rule that stops a destination with three attempts from opening a circuit.

Approach

  1. Name the exact-deque version and then reject it as the default. Holding timestamps and advancing a tail pointer past anything older than now minus 60 seconds is a correct two-pointer window at amortised O(1) per attempt, but its memory tracks in-window traffic, so one destination in a retry storm holds hundreds of thousands of entries while thousands of quiet destinations hold none.
  2. Use a ring of 60 one-second buckets per destination, each bucket a pair of counters for attempts and failures. On an attempt, advance the ring by the elapsed whole seconds, zeroing at most min(elapsed, 60) buckets, then increment the head. That is amortised O(1) with a fixed footprint per destination.
  3. State the footprint: 60 buckets times two 4-byte counters is 480 bytes of payload per destination, so 40,000 destinations is roughly 20 to 25 MB with per-entry overhead, bounded by the catalogue rather than by the rate. The cost is granularity, since the oldest bucket ages out in whole seconds, which is far tighter than the decision needs.
  4. Require a minimum sample before the circuit may open. A destination with three attempts and three failures reads as 100 percent and is not evidence; a floor of roughly 20 attempts in the window makes the ratio meaningful, and below that floor use a run of consecutive failures as the trigger instead.

Follow-up

  • The fleet is 30 instances and each sees roughly a thirtieth of a destination's traffic. Where does the rate actually live, and what does a per-instance answer get wrong?
  • A destination answers in 9.5 seconds and succeeds. It is not failing but it is consuming your per-destination concurrency. What signal should open the circuit here?

Find overlapping job attempts and peak concurrency from lease records

Medium · sweep line · intervals · leases

A day of job_run history yields about 50,000,000 attempt records: (job_run_id, job_type, attempt, started_at, finished_at which is NULL when the worker died, lease_expires_at). Leases expire on a clock, so a job that outran its lease ran twice. Produce (a) every job_run_id whose attempts overlapped in wall-clock time and (b) the peak number of simultaneously running attempts per job_type with the minute it occurred. Target O(n log n). State how you treat a NULL finished_at and what clock skew does to your answer.

Approach

  1. Define the interval before sorting anything: an attempt occupies [started_at, COALESCE(finished_at, lease_expires_at)). finished_at is observed and lease_expires_at is only a promise, so every attempt without a finish contributes an estimate and the whole result is a lower bound on overlap rather than an exact count.
  2. For peak concurrency, sweep: emit 2n endpoints, sort by (timestamp, kind) with ends ordered before starts at equal timestamps, then walk the sequence maintaining a counter per job_type and record each type's maximum with its timestamp. O(n log n) dominated by the sort, O(n) space, or O(1) extra if the sort is external and the walk streams.
  3. For overlap detection, do not compare attempts pairwise. A single global sort by (job_run_id, started_at) gives both the grouping and the order; within a group, keep the maximum end seen so far and report an overlap exactly when the next start is less than that running maximum, which is one linear pass after the sort.
  4. Half-open intervals matter and are easy to get wrong: with closed intervals an attempt ending at the same millisecond another begins reads as concurrency two, and across 50,000,000 records that artefact swamps the real signal.

Follow-up

  • A handler is not idempotent and you have found 400 overlapping jobs. Which of them actually caused damage, and what would you query to find out?
  • Peak concurrency for one job_type is 4 against a configured cap of 4. Is the cap working, or is the data hiding attempts that never started?

Canonicalise a request body into a stable idempotency fingerprint

Medium · parsing · canonicalisation · hashing

idempotency_key.request_fingerprint is a SHA-256 over the method, path and canonicalised body, and a retry whose fingerprint differs must be rejected with 422 rather than served the stored response. Write the canonicaliser. Bodies are JSON up to 256 KB nested at most 32 levels; clients vary key order, whitespace and unicode escaping, and some send 64-bit ids as JSON numbers. Produce a deterministic byte string such that semantically identical bodies match and any semantic difference does not. State your complexity and name two normalisations you refuse to perform.

Approach

  1. Parse once into a tree, then re-serialise under fixed rules: object keys sorted, array order preserved, one escaping convention, no insignificant whitespace. Parsing is O(n) and sorting keys is O(k log k) per object, so O(n log n) overall with O(depth) stack, and the 32-level cap is enforced during parsing because hostile nesting is how a canonicaliser becomes a stack overflow.
  2. Sort keys by their UTF-8 bytes and say why the obvious implementation is wrong in some runtimes: a default string comparison that orders by UTF-16 code units places surrogate pairs, meaning code points from U+10000 up, below U+E000 to U+FFFF, which is not UTF-8 byte order, so two services written in different languages disagree on the same document.
  3. Do not re-encode numbers through a double. IEEE-754 binary64 represents integers exactly only up to 2^53, so normalising a 19-digit id through a float changes it, and 1 against 1.0 cannot be reconciled without deciding whether they are the same value. Preserve the literal token, and require ids as strings at the API boundary if you want them comparable.
  4. Reject duplicate keys rather than picking one. JSON permits them and parsers disagree, most keeping the last, so any choice you make ties the fingerprint to a parser detail that the code handling the request does not necessarily share.

Follow-up

  • A client sends the same logical request with an extra field your API ignores. Same key, different fingerprint, so you return 422. Is that the right answer?
  • Where does the fingerprint get computed relative to request decompression and the body-size limit?

Find version gaps and relay lag with window functions

Medium · window functions · event tables · frame semantics

outbox_event holds event_id, aggregate_type, aggregate_id, aggregate_version, event_type, payload, status ('pending','published','dead'), attempts, created_at, published_at. A projection is missing rows and you must decide whether the relay skipped events or the consumer dropped them. Write three queries over the last seven days: one listing every aggregate_id whose published aggregate_version sequence has a hole, one giving per-day counts with a running total, and one returning the newest published event per aggregate. For each, say where the window function is evaluated relative to WHERE and LIMIT. PostgreSQL 16.

Approach

  1. Gaps: compute lead(aggregate_version) OVER (PARTITION BY aggregate_id ORDER BY aggregate_version) in a subquery, then filter next_version <> aggregate_version + 1 in the outer query. Window functions are evaluated after WHERE, GROUP BY and HAVING and before the outer ORDER BY and LIMIT, so the predicate cannot sit in the same WHERE clause and PostgreSQL 16 has no QUALIFY.
  2. Say what the seven-day filter does to the answer: it truncates every partition, so the first row per aggregate has no predecessor inside the window and a hole spanning the boundary is invisible. Widen the window, or join to resource.version as the authority for the true maximum.
  3. Running total: SELECT date_trunc('day', created_at) AS d, count() AS n, sum(count()) OVER (ORDER BY date_trunc('day', created_at) ROWS UNBOUNDED PRECEDING). An aggregate inside a window call is legal because grouping runs before windowing. The grouping key is unique per row here so ROWS and RANGE agree, but write the frame anyway — over ungrouped rows with tied timestamps the default RANGE frame pulls in every peer row and the total jumps.
  4. Newest per aggregate: DISTINCT ON (aggregate_id) ... ORDER BY aggregate_id, aggregate_version DESC is the cheap PostgreSQL-only form when an index matches that order; row_number() OVER (PARTITION BY aggregate_id ORDER BY aggregate_version DESC) = 1 is the portable form and needs a subquery for the same evaluation-order reason as the gap query.

Follow-up

  • Relay failover redelivers events. Does a duplicate break the gap query, and how would you detect one from this table alone?
  • Turn the gap check into a continuous monitor rather than a query someone runs after an incident. What does it watch?

Denormalise tenant onto revisions and backfill it live

Hard · denormalisation · online migration · backfill

resource_revision (revision_id, resource_id, version, actor_user_id, change_kind, patch, request_id, created_at) has 400M rows and no tenant column; tenant_id lives only on resource. Two reads need it: a tenant-scoped audit feed ordered by created_at DESC, and an offboarding purge. Both join back to resource today. Justify adding tenant_id to resource_revision against those two reads, name the anomaly the copy introduces and the constraint that prevents it, then give the ordered migration for a live table taking 1.2k writes/second — the lock each step takes, how the backfill is batched, and where each step stops being reversible. PostgreSQL 16.

Approach

  1. Justify from the access path rather than from taste. Without the column, the audit feed either scans resource_revision by created_at and discards other tenants' rows, or resolves the tenant's resource_ids first and probes with them — both proportional to the tenant's whole history rather than to one page. With (tenant_id, created_at DESC, revision_id DESC) it is a seek that stops at 50 rows, and the purge becomes a ranged delete instead of a join.
  2. Name the cost exactly: a second copy of a fact can disagree with the first. Make the disagreement unwritable rather than documented — add UNIQUE (resource_id, tenant_id) on resource so it can serve as a foreign-key target, then FOREIGN KEY (resource_id, tenant_id) REFERENCES resource (resource_id, tenant_id) on the revision table. A revision can then only ever carry its parent's tenant.
  3. Step one, expand: ALTER TABLE resource_revision ADD COLUMN tenant_id BIGINT NULL, with no default, so it is a catalogue change and no rewrite. It still needs ACCESS EXCLUSIVE for an instant, and that instant queues behind the longest open transaction on the table while every later query queues behind it — set lock_timeout to 2s and retry rather than wait.
  4. Step two, dual-write: deploy the writer that populates tenant_id on every new revision while reads still use the join. Reversible by redeploying the previous build, because nothing reads the column yet.

Follow-up

  • The backfill is half finished and a rollback is required. What state is the table in, and what does the previous build do with a half-populated column?
  • How do you verify the backfill actually finished, given rows are still being inserted while it runs?

What programming languages are you proficient in, and how have you applied them in past projects?

Medium · Technical / Domain Questions

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

What are the key considerations when developing software for energy management systems?

Medium · Technical / Domain Questions

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

How do you ensure code quality and maintainability?

Medium · Technical / Domain Questions

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

How would you design a software solution to improve energy efficiency in a given context?

Medium · Problem-Solving / Case Studies

Approach

  1. Fix the scope first: who calls this, how often, and what they do when it fails.
  2. Name the read and write paths separately; they rarely have the same bottleneck.
  3. Choose a partition key and say what query it makes expensive.
  4. State the consistency you need, and where you are willing to be stale.

Follow-up

  • What breaks first when traffic grows ten times?
  • How does this behave when that dependency is down for an hour?

What steps would you take to gather requirements for a new software project?

Medium · Problem-Solving / Case Studies

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

Explain how you would approach optimizing an existing software application for better performance.

Medium · Problem-Solving / Case Studies

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

How do you prioritize tasks when managing multiple projects?

Medium · Problem-Solving / Case Studies

Approach

  1. Clarify what is being asked and what a complete answer contains.
  2. State your assumptions explicitly before working the problem.
  3. Say what you would check first and why it is the highest-information step.
  4. Work from the requirement backwards to the design.

Follow-up

  • What assumption would you test first?
  • How would you know your answer was wrong?

Can you explain how you approach debugging a complex software issue?

Medium · Technical / Domain Questions

Approach

  1. Establish what changed and when, before forming any theory.
  2. Pick a bisection that eliminates candidates whichever way it turns out.
  3. Check the instrumentation before believing the symptom.
  4. Separate the trigger from the cause; the deploy is rarely the bug.

Follow-up

  • What would you look at first, and what would it rule out?
  • How would you tell a cause from a coincidence here?

Given a scenario where a software system fails, how would you troubleshoot and resolve the issue?

Medium · Problem-Solving / Case Studies

Approach

  1. Establish what changed and when, before forming any theory.
  2. Pick a bisection that eliminates candidates whichever way it turns out.
  3. Check the instrumentation before believing the symptom.
  4. Separate the trigger from the cause; the deploy is rarely the bug.

Follow-up

  • What would you look at first, and what would it rule out?
  • How would you tell a cause from a coincidence here?

Suggested practice checklist

Built from the rounds and topics EDF candidates report.

Day 1 — Map the EDF loop

  • Write out the reported sequence: Initial Screening, Technical Interviews, Practical Coding Exercises, Discussions About Past Projects.
  • For each round, write one sentence on what it is judging, from the description above, and mark the one you are least ready for.

Deliverable: A one-page map of the 4 reported rounds, with the weakest marked.

Day 2 — Work Nuclear industry domain knowledge

  • Spend the session on Nuclear industry domain knowledge, which EDF candidates report being tested on.
  • Write one worked example in Nuclear industry domain knowledge and time yourself on it.

Deliverable: One timed worked example in Nuclear industry domain knowledge.

Day 3 — Work Power plant operations overview (nuclear centrale process)

  • Spend the session on Power plant operations overview (nuclear centrale process), which EDF candidates report being tested on.
  • Write one worked example in Power plant operations overview (nuclear centrale process) and time yourself on it.

Deliverable: One timed worked example in Power plant operations overview (nuclear centrale process).

Day 4 — Work Earned Value Management (EVM) / comprehension of Value Acquise

  • Spend the session on Earned Value Management (EVM) / comprehension of Value Acquise, which EDF candidates report being tested on.
  • Write one worked example in Earned Value Management (EVM) / comprehension of Value Acquise and time yourself on it.

Deliverable: One timed worked example in Earned Value Management (EVM) / comprehension of Value Acquise.

Day 5 — Answer out loud: Technical / Domain Questions

  • Answer aloud, timed: What programming languages are you proficient in, and how have you applied them in past projects?
  • Answer aloud, timed: Can you explain how you approach debugging a complex software issue?

Deliverable: Spoken answers to 2 reported Technical / Domain Questions question(s), under time.

Day 6 — Answer out loud: Behavioral / Leadership

  • Answer aloud, timed: Describe a challenging team project you worked on. What was your role, and how did you contribute to its success?
  • Answer aloud, timed: How do you handle conflicts or disagreements within a team?

Deliverable: Spoken answers to 2 reported Behavioral / Leadership question(s), under time.

Day 7 — Answer out loud: Problem-Solving / Case Studies

  • Answer aloud, timed: Given a scenario where a software system fails, how would you troubleshoot and resolve the issue?
  • Answer aloud, timed: How would you design a software solution to improve energy efficiency in a given context?

Deliverable: Spoken answers to 2 reported Problem-Solving / Case Studies question(s), under time.

Behavioural preparation

Behavioural rounds judge the decision you made and what it cost.

Describe your experience with CI/CD practices and tools.

Medium · Technical / Domain Questions

Approach

  1. Pick a story where you made the decision, not one where you watched it.
  2. State the situation in two sentences and spend the rest on the reasoning.
  3. Give the blast radius: what could have broken, and what you measured.
  4. Name the disagreement and how you resolved it with evidence.

Follow-up

  • What would you do differently if you ran that again?
  • How did you know your change caused the improvement?

Describe a challenging team project you worked on. What was your role, and how did you contribute to its succe

Medium · Behavioral / Leadership

Describe a challenging team project you worked on. What was your role, and how did you contribute to its success?

Approach

  1. Pick a story where you made the decision, not one where you watched it.
  2. State the situation in two sentences and spend the rest on the reasoning.
  3. Give the blast radius: what could have broken, and what you measured.
  4. Name the disagreement and how you resolved it with evidence.

Follow-up

  • What would you do differently if you ran that again?
  • How did you know your change caused the improvement?

How do you handle conflicts or disagreements within a team?

Medium · Behavioral / Leadership

Approach

  1. Pick a story where you made the decision, not one where you watched it.
  2. State the situation in two sentences and spend the rest on the reasoning.
  3. Give the blast radius: what could have broken, and what you measured.
  4. Name the disagreement and how you resolved it with evidence.

Follow-up

  • What would you do differently if you ran that again?
  • How did you know your change caused the improvement?

Can you provide an example of how you adapted to a significant change in a project?

Medium · Behavioral / Leadership

Approach

  1. Pick a story where you made the decision, not one where you watched it.
  2. State the situation in two sentences and spend the rest on the reasoning.
  3. Give the blast radius: what could have broken, and what you measured.
  4. Name the disagreement and how you resolved it with evidence.

Follow-up

  • What would you do differently if you ran that again?
  • How did you know your change caused the improvement?

What motivates you to work in the energy sector, specifically at EDF?

Medium · Behavioral / Leadership

Approach

  1. Pick a story where you made the decision, not one where you watched it.
  2. State the situation in two sentences and spend the rest on the reasoning.
  3. Give the blast radius: what could have broken, and what you measured.
  4. Name the disagreement and how you resolved it with evidence.

Follow-up

  • What would you do differently if you ran that again?
  • How did you know your change caused the improvement?

Describe a time when you had to learn a new technology or skill quickly. How did you approach it?

Medium · Behavioral / Leadership

Approach

  1. Pick a story where you made the decision, not one where you watched it.
  2. State the situation in two sentences and spend the rest on the reasoning.
  3. Give the blast radius: what could have broken, and what you measured.
  4. Name the disagreement and how you resolved it with evidence.

Follow-up

  • What would you do differently if you ran that again?
  • How did you know your change caused the improvement?