Interview guides · Antora
Antora Software Engineer Interview Guide
Antora Software Engineer interview guide: reported rounds, questions and how candidates describe the process.
The 60-second brief
As a Software Engineer (specifically within the Controls & Software domain) at Antora, you are the architect of the "brain" powering next-generation thermal energy storage. You are not simply writing code for abstract applications; you are building the logic that enables industrial facilities to transition to clean, low-cost energy. Your work sits at the critical intersection of physical hardware—such as thermal batteries and industrial boilers—and the digital systems that keep them running safely and efficiently. This role is high-impact and requires a startup mindset. You will own the full lifecycle of software for Antora’s energy modules, from initial design and logic development to site-wide commissioning. Because you are working with high-stakes, high-temperature industrial environments, your contributions directly impact the reliability and safety of infrastructure.
This guide is scoped to a Software Engineer candidate at Antora.
Focus areas
- PLC Programming
- SCADA Development
- System Architecture
The Antora interview process
Antora candidates report 3 rounds over 3-5 weeks. The stages below are what candidates describe, not a published process.
Initial Screening
Gauge your technical background and interest in the company's mission.
What to demonstrate
- Gauge your technical background and interest in the company's mission
- Depth in PLC Programming
How to prepare
- Be able to walk your CV end to end in two minutes, and say why this company specifically.
- Have your salary expectations, notice period and location constraints ready, and ask for the rest of the loop in writing.
Technical Deep-Dives
Participate in a series of technical interviews focusing on hands-on experience.
What to demonstrate
- Participate in a series of technical interviews focusing on hands-on experience
- Depth in PLC Programming
How to prepare
- Answer aloud and timed: How do you approach the design of Process Control Narratives (PCNs) and State Diagrams for complex systems?
- Answer aloud and timed: What is your strategy for ensuring software reliability in high-stakes industrial environments?
Behavioral Interviews
Engage with members of the engineering team to discuss past experiences.
What to demonstrate
- Engage with members of the engineering team to discuss past experiences
- Depth in PLC Programming
How to prepare
- Prepare three examples from your own work, each with a decision you made and an outcome you can quantify.
- Re-read the description of the behavioral interviews above and write down what you would ask to confirm before it.
Where candidates lose points
Prepare for "Low-Energy" Interviewers
As noted in some candidate experiences, you may encounter an interviewer who seems disengaged. Do not let this affect your performance; remain professional, high-energy, and focused on delivering your best answers regardless of the interviewer's demeanor.
Be Specific About Tools
When discussing your experience, mention specific versions of software (e.g., Studio 5000) and specific hardware components. This demonstrates the "Hardware Fluency" required for the role.
Align with the Mission
Antora is a mission-driven company. Briefly articulating your passion for decarbonizing industrial heat can help you stand out as a cultural fit.
Prepare a concise summary of your most complex project
Focus on the specific logic challenges you faced and how you validated your solution under time pressure.
Questions & practice
Identify the heaviest tenants in a five-minute window under memory pressure
Medium · top-k · heavy hitters · streaming
The edge service handles about 3,000 requests per second across roughly 50,000 tenants, peaking near 9,000. Expose the 50 heaviest tenants by request count over the trailing five minutes so limits can be tightened before one tenant's backfill starves the fleet. You may not retain five minutes of raw records. Give the exact solution and its memory, then the bounded-memory approximation with its error stated as a formula, and say which you would ship and at what tenant cardinality that choice changes.
Approach
- Do the exact version first, because it is affordable at this cardinality: a ring of 300 one-second counters per tenant, advanced lazily, is 1,200 bytes of counters per tenant and roughly 60 to 90 MB for 50,000 tenants with overhead. Carry a running total and subtract the bucket you overwrite so a window read is O(1) rather than 300 adds.
- Extract the top 50 with a size-k min-heap over the tenant sums: O(d log k) for d tenants, against O(d log d) to sort them all. Maintaining the heap continuously instead of on query requires a tenant-to-heap-index map, because incrementing a count already inside the heap means sifting from a known position, and without that map you rebuild the heap on every request.
- State the approximation precisely rather than gesturing at sketches. Misra-Gries with m counters retains every item whose true count exceeds N/(m+1), and each retained count underestimates the truth by at most N/(m+1). With m = 1,000 and N = 900,000 requests in the window the error is roughly 900 requests, which is fine for spotting a tenant sending 50,000 and useless for ranking two tenants 200 apart.
- Say what breaks when the window slides: Misra-Gries and Space-Saving are insert-only and cannot be decremented as records age out. The workable construction is one summary per sub-window, say ten seconds, with 30 summaries merged at query time, and the merged error is the sum of the per-summary errors, so the bound degrades linearly in the number of sub-windows.
Follow-up
- The heaviest tenant is heavy because of one export job rather than user traffic. Should the limiter treat those as the same tenant?
- Two tenants sit tied at the boundary of the top 50. Does your answer flap, and does the flapping matter?
Track a rolling failure rate per destination for circuit decisions
Easy · sliding window · ring buffer · circuit breaker
The egress service delivers about 1,500 webhooks per second across roughly 40,000 destinations, each call bounded by a 10 second timeout. Maintain, per destination, the failure rate over the trailing 60 seconds so a caller can ask before dispatch whether the circuit should open. Attempts arrive as (destination_id, finished_at_ms, outcome). Requirement: amortised O(1) per attempt, with total memory bounded by the destination count rather than by traffic. Give the structure, its exact memory, and the rule that stops a destination with three attempts from opening a circuit.
Approach
- Name the exact-deque version and then reject it as the default. Holding timestamps and advancing a tail pointer past anything older than now minus 60 seconds is a correct two-pointer window at amortised O(1) per attempt, but its memory tracks in-window traffic, so one destination in a retry storm holds hundreds of thousands of entries while thousands of quiet destinations hold none.
- Use a ring of 60 one-second buckets per destination, each bucket a pair of counters for attempts and failures. On an attempt, advance the ring by the elapsed whole seconds, zeroing at most min(elapsed, 60) buckets, then increment the head. That is amortised O(1) with a fixed footprint per destination.
- State the footprint: 60 buckets times two 4-byte counters is 480 bytes of payload per destination, so 40,000 destinations is roughly 20 to 25 MB with per-entry overhead, bounded by the catalogue rather than by the rate. The cost is granularity, since the oldest bucket ages out in whole seconds, which is far tighter than the decision needs.
- Require a minimum sample before the circuit may open. A destination with three attempts and three failures reads as 100 percent and is not evidence; a floor of roughly 20 attempts in the window makes the ratio meaningful, and below that floor use a run of consecutive failures as the trigger instead.
Follow-up
- The fleet is 30 instances and each sees roughly a thirtieth of a destination's traffic. Where does the rate actually live, and what does a per-instance answer get wrong?
- A destination answers in 9.5 seconds and succeeds. It is not failing but it is consuming your per-destination concurrency. What signal should open the circuit here?
Diff a projection against the primary without per-row point reads
Hard · reconciliation · range hashing · throttling
The listing projection has drifted and some rows show a stale version. The primary holds 40,000,000 resource rows across 12,000 tenants while serving 1,200 writes and 14,000 reads per second. The obvious repair, reading each resource row and comparing its version against the projection, is correct and would eventually finish. Explain precisely why it is unacceptable here, then give a diff that finds the differing rows, state its complexity, and make it safe to run against a live primary. Replication lag is usually under 100 ms and is not bounded.
Approach
- Quantify the naive cost rather than calling it slow: 40,000,000 point reads at even 0.5 ms each is over five hours serialised, and the only lever is concurrency, which is exactly what you cannot spend. The primary's pool is sized for the write path, and 40,000,000 random reads evict the buffer cache that sustains the 85 percent cache hit rate, so the audit degrades the system it is auditing.
- Replace random access with one ordered pass per side. Both sides can be read in (tenant_id, resource_id) order, which is a sequential scan on each and a merge join in O(n) time and O(1) memory. For a dense diff that is the whole answer, and it reads the primary once instead of 40,000,000 times.
- For the expected sparse case, compare range hashes instead of rows: partition the key space, compute per range an order-independent aggregate over hash(resource_id, version), compare aggregates, and descend only into ranges that differ. With d differing rows and branching factor B, at most d ranges mismatch per level, so the drill-down examines O(d log_B(n/d)) ranges and reads full rows only in mismatching leaves.
- Aggregate with a sum modulo 2^64 or a multiset hash, never XOR. XOR is order-independent but self-cancelling, so two rows wrong in the same way, or a row duplicated on one side, leave the range aggregate matching and the range is declared clean.
Follow-up
- The diff reports 900 stale rows. How do you decide between patching those rows and rebuilding the projection from resource_revision?
- Same job, but the projection lives in a search index that cannot be scanned in key order. What changes?
Find version gaps and relay lag with window functions
Medium · window functions · event tables · frame semantics
outbox_event holds event_id, aggregate_type, aggregate_id, aggregate_version, event_type, payload, status ('pending','published','dead'), attempts, created_at, published_at. A projection is missing rows and you must decide whether the relay skipped events or the consumer dropped them. Write three queries over the last seven days: one listing every aggregate_id whose published aggregate_version sequence has a hole, one giving per-day counts with a running total, and one returning the newest published event per aggregate. For each, say where the window function is evaluated relative to WHERE and LIMIT. PostgreSQL 16.
Approach
- Gaps: compute lead(aggregate_version) OVER (PARTITION BY aggregate_id ORDER BY aggregate_version) in a subquery, then filter next_version <> aggregate_version + 1 in the outer query. Window functions are evaluated after WHERE, GROUP BY and HAVING and before the outer ORDER BY and LIMIT, so the predicate cannot sit in the same WHERE clause and PostgreSQL 16 has no QUALIFY.
- Say what the seven-day filter does to the answer: it truncates every partition, so the first row per aggregate has no predecessor inside the window and a hole spanning the boundary is invisible. Widen the window, or join to resource.version as the authority for the true maximum.
- Running total: SELECT date_trunc('day', created_at) AS d, count() AS n, sum(count()) OVER (ORDER BY date_trunc('day', created_at) ROWS UNBOUNDED PRECEDING). An aggregate inside a window call is legal because grouping runs before windowing. The grouping key is unique per row here so ROWS and RANGE agree, but write the frame anyway — over ungrouped rows with tied timestamps the default RANGE frame pulls in every peer row and the total jumps.
- Newest per aggregate: DISTINCT ON (aggregate_id) ... ORDER BY aggregate_id, aggregate_version DESC is the cheap PostgreSQL-only form when an index matches that order; row_number() OVER (PARTITION BY aggregate_id ORDER BY aggregate_version DESC) = 1 is the portable form and needs a subquery for the same evaluation-order reason as the gap query.
Follow-up
- Relay failover redelivers events. Does a duplicate break the gap query, and how would you detect one from this table alone?
- Turn the gap check into a continuous monitor rather than a query someone runs after an incident. What does it watch?
Replace offset paging on the resource feed with keyset
Easy · keyset pagination · composite index · sort order
resource holds resource_id, tenant_id, owner_user_id, title, body_ref, version, status ('draft','active','archived','deleted'), created_at, updated_at, deleted_at, with an index on (tenant_id, status, updated_at DESC, resource_id DESC). The listing endpoint returns active resources for one tenant, newest update first, 50 per page, today with LIMIT 50 OFFSET n. Tenants reach page 400 and rows are created while they read. Write the keyset query, define what the cursor carries and how it is encoded, and say which part of the index each predicate uses. Assume PostgreSQL 16.
Approach
- Name the two failures separately. OFFSET 20000 makes the server produce and discard 20,000 rows, so page cost grows with depth rather than with page size. Independently, any write that changes how many rows sort above the offset moves the window between two fetches, and the direction decides which anomaly you get: an insert lands at the head of updated_at DESC and pushes already-returned rows down past the boundary, so they are returned a second time; a delete above the offset, or a row whose updated_at is bumped above the cursor, pulls rows up and one is never returned at all. Nothing in the response reveals either.
- Write the seek: WHERE tenant_id = $1 AND status = 'active' AND (updated_at, resource_id) < ($2, $3) ORDER BY updated_at DESC, resource_id DESC LIMIT 50. The row-value comparison is one index range rather than a disjunction, and both columns are NOT NULL, which is what makes that comparison well defined.
- Map each predicate onto the index: tenant_id and status are equality on the leading columns, (updated_at, resource_id) is the range, and the ORDER BY matches the index order so no Sort node appears and the scan stops after 50 rows. The DESC in the definition only matters for mixed directions — a plain ascending btree on the same columns is read backwards for this query.
- Put both sort columns in the cursor and nothing the client can tamper with into another tenant: base64 of (updated_at, resource_id), validated server-side, with tenant_id taken from the principal.
Follow-up
- The client asks for 'jump to page 400'. What do you offer instead, and what does the honest version cost?
- Sort order becomes user-selectable across four columns. How many indexes is that, and which would you refuse to add?
How have you handled "field-found" challenges during the commissioning phase of a project?
Medium · Technical & Domain Expertise
Approach
- Clarify what is being asked and what a complete answer contains.
- State your assumptions explicitly before working the problem.
- Say what you would check first and why it is the highest-information step.
- Work from the requirement backwards to the design.
Follow-up
- What assumption would you test first?
- How would you know your answer was wrong?
How do you approach the design of Process Control Narratives (PCNs) and State Diagrams for complex systems?
Medium · Technical & Domain Expertise
Approach
- Clarify what is being asked and what a complete answer contains.
- State your assumptions explicitly before working the problem.
- Say what you would check first and why it is the highest-information step.
- Work from the requirement backwards to the design.
Follow-up
- What assumption would you test first?
- How would you know your answer was wrong?
What is your strategy for ensuring software reliability in high-stakes industrial environments?
Medium · Technical & Domain Expertise
Approach
- Clarify what is being asked and what a complete answer contains.
- State your assumptions explicitly before working the problem.
- Say what you would check first and why it is the highest-information step.
- Work from the requirement backwards to the design.
Follow-up
- What assumption would you test first?
- How would you know your answer was wrong?
How do you interpret and provide red-lines for complex electrical schematics or P&IDs?
Medium · Technical & Domain Expertise
Approach
- Clarify what is being asked and what a complete answer contains.
- State your assumptions explicitly before working the problem.
- Say what you would check first and why it is the highest-information step.
- Work from the requirement backwards to the design.
Follow-up
- What assumption would you test first?
- How would you know your answer was wrong?
How do you leverage modern tools or AI to streamline your technical documentation or troubleshooting?
Medium · Behavioral & Situational
Approach
- Establish what changed and when, before forming any theory.
- Pick a bisection that eliminates candidates whichever way it turns out.
- Check the instrumentation before believing the symptom.
- Separate the trigger from the cause; the deploy is rarely the bug.
Follow-up
- What would you look at first, and what would it rule out?
- How would you tell a cause from a coincidence here?
Suggested practice checklist
Built from the rounds and topics Antora candidates report.
Day 1 — Map the Antora loop
- Write out the reported sequence: Initial Screening, Technical Deep-Dives, Behavioral Interviews.
- For each round, write one sentence on what it is judging, from the description above, and mark the one you are least ready for.
Deliverable: A one-page map of the 3 reported rounds, with the weakest marked.
Day 2 — Work PLC Programming
- Spend the session on PLC Programming, which Antora candidates report being tested on.
- Write one worked example in PLC Programming and time yourself on it.
Deliverable: One timed worked example in PLC Programming.
Day 3 — Work SCADA Development
- Spend the session on SCADA Development, which Antora candidates report being tested on.
- Write one worked example in SCADA Development and time yourself on it.
Deliverable: One timed worked example in SCADA Development.
Day 4 — Work System Architecture
- Spend the session on System Architecture, which Antora candidates report being tested on.
- Write one worked example in System Architecture and time yourself on it.
Deliverable: One timed worked example in System Architecture.
Day 5 — Answer out loud: Technical & Domain Expertise
- Answer aloud, timed: How have you handled "field-found" challenges during the commissioning phase of a project?
- Answer aloud, timed: Can you describe your experience working with PLC and SCADA systems in a "greenfield" environment?
Deliverable: Spoken answers to 2 reported Technical & Domain Expertise question(s), under time.
Day 6 — Answer out loud: Behavioral & Situational
- Answer aloud, timed: Tell me about a time you had to pivot quickly due to changing project requirements.
- Answer aloud, timed: How do you handle high-pressure situations when a system is not performing as expected onsite?
Deliverable: Spoken answers to 2 reported Behavioral & Situational question(s), under time.
Day 7 — Dry run for Antora
- Run one full mock under time, then write down the two questions you most want to ask your interviewers.
Deliverable: A completed timed mock and two questions to ask.
Behavioural preparation
Behavioural rounds judge the decision you made and what it cost.
Can you describe your experience working with PLC and SCADA systems in a "greenfield" environment?
Medium · Technical & Domain Expertise
Approach
- Pick a story where you made the decision, not one where you watched it.
- State the situation in two sentences and spend the rest on the reasoning.
- Give the blast radius: what could have broken, and what you measured.
- Name the disagreement and how you resolved it with evidence.
Follow-up
- What would you do differently if you ran that again?
- How did you know your change caused the improvement?
Tell me about a time you had to pivot quickly due to changing project requirements.
Medium · Behavioral & Situational
Approach
- Pick a story where you made the decision, not one where you watched it.
- State the situation in two sentences and spend the rest on the reasoning.
- Give the blast radius: what could have broken, and what you measured.
- Name the disagreement and how you resolved it with evidence.
Follow-up
- What would you do differently if you ran that again?
- How did you know your change caused the improvement?
How do you handle high-pressure situations when a system is not performing as expected onsite?
Medium · Behavioral & Situational
Approach
- Pick a story where you made the decision, not one where you watched it.
- State the situation in two sentences and spend the rest on the reasoning.
- Give the blast radius: what could have broken, and what you measured.
- Name the disagreement and how you resolved it with evidence.
Follow-up
- What would you do differently if you ran that again?
- How did you know your change caused the improvement?
Describe your experience collaborating with cross-functional teams, such as mechanical or process engineers.
Medium · Behavioral & Situational
Approach
- Pick a story where you made the decision, not one where you watched it.
- State the situation in two sentences and spend the rest on the reasoning.
- Give the blast radius: what could have broken, and what you measured.
- Name the disagreement and how you resolved it with evidence.
Follow-up
- What would you do differently if you ran that again?
- How did you know your change caused the improvement?
Why are you interested in transitioning into the thermal energy storage space?
Medium · Behavioral & Situational
Approach
- Pick a story where you made the decision, not one where you watched it.
- State the situation in two sentences and spend the rest on the reasoning.
- Give the blast radius: what could have broken, and what you measured.
- Name the disagreement and how you resolved it with evidence.
Follow-up
- What would you do differently if you ran that again?
- How did you know your change caused the improvement?